Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37038759

RESUMO

AIMS: To allow timely initiation of anticoagulation therapy for the prevention of stroke, the European guidelines on atrial fibrillation (AF) recommend remote monitoring (RM) of device-detected atrial high-rate episodes (AHREs) and progression of arrhythmia duration along pre-specified strata (6 min…<1 h, 1 h…<24 h, ≥ 24 h). We used the MATRIX registry data to assess the capability of a single-lead implantable cardioverter-defibrillator (ICD) with atrial sensing dipole (DX ICD system) to follow this recommendation in patients with standard indication for single-chamber ICD. METHODS AND RESULTS: In 1841 DX ICD patients with daily automatic RM transmissions, electrograms of first device-detected AHREs per patient in each duration stratum were adjudicated, and the corresponding positive predictive values (PPVs) for the detections to be true atrial arrhythmia were calculated. Moreover, the incidence and progression of new-onset AF was assessed in 1451 patients with no AF history. A total of 610 AHREs ≥6 min were adjudicated. The PPV was 95.1% (271 of 285) for episodes 6min…<1 h, 99.6% (253/254) for episodes 1 h…<24 h, 100% (71/71) for episodes ≥24 h, or 97.5% for all episodes (595/610). The incidence of new-onset AF was 8.2% (119/1451), and in 31.1% of them (37/119), new-onset AF progressed to a higher duration stratum. Nearly 80% of new-onset AF patients had high CHA2DS2-VASc stroke risk, and 70% were not on anticoagulation therapy. Age was the only significant predictor of new-onset AF. CONCLUSION: A 99.7% detection accuracy for AHRE ≥1 h in patients with DX ICD systems in combination with daily RM allows a reliable guideline-recommended screening for subclinical AF and monitoring of AF-duration progression.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/epidemiologia , Desfibriladores Implantáveis/efeitos adversos , Átrios do Coração , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Anticoagulantes
3.
Trials ; 18(1): 208, 2017 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-28472974

RESUMO

BACKGROUND: The efficacy of dual-chamber cardiac pacing in neuro-mediated reflex syncope with a cardio-inhibitory response to the Tilt-Table test (TT) has not been definitively assessed so far. The lack of reproducibility of results from previous studies may be partially explained by discrepancies in subject selection and some weaknesses in design and methods. The European Society of Cardiology (ESC) has set a class IIb indication to pacemaker implantation in this population recommending further research. METHODS/DESIGN: The BIOSync study is a multicenter, patient- and outcome-assessor-blind, randomized, parallel-arm, placebo-controlled trial with the objective of assessing the clinical benefit of cardiac pacing in patients with frequently recurrent reflex syncope, suspected (but not proven) to be triggered by asystolic pauses as showing a VASIS 2B response to the TT (>3-s pause regardless of blood pressure drop). The primary and secondary endpoints are time to first post-implantation recurrence of syncope or the combination of pre-syncope or syncope, respectively. One hundred and twenty-eight consenting patients will be 1:1 randomized to dual-chamber cardiac pacing 'on' or 'off' after pacemaker implantation, and followed up until the first adjudicated primary endpoint event for a maximum of 2 years. The so-called Closed Loop Stimulation function on top of dual-chamber pacing is the pacing mode selected in the study active arm. Participating patients are asked to self-report syncopal symptoms at least every 3 months with self-administered questionnaires addressed to an independent Adjudication Committee. Patients and members of the Adjudicating Committee are blinded to randomization. The study is designed to detect a 40% relative reduction in the 2-year incidence of syncopal recurrences with 80% statistical power. DISCUSSION: The BIOSync study is designed to definitively assess the benefit of pacing against placebo in reflex syncope patients with a cardio-inhibitory response to the TT. The study will also provide important information on the efficiency of the TT in appropriately selecting reflex syncope patients for cardiac pacing. TRIAL REGISTRATION: ClinicalTrials.gov, identifier: NCT02324920 (27 October 2016, date last accessed).


Assuntos
Estimulação Cardíaca Artificial , Marca-Passo Artificial , Síncope Vasovagal/terapia , Teste da Mesa Inclinada , Função Ventricular Esquerda , Função Ventricular Direita , Estimulação Cardíaca Artificial/efeitos adversos , Protocolos Clínicos , Desenho de Equipamento , Europa (Continente) , Hemodinâmica , Humanos , Valor Preditivo dos Testes , Recidiva , Projetos de Pesquisa , Síncope Vasovagal/diagnóstico , Síncope Vasovagal/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
4.
Heart Rhythm ; 5(3): 387-90, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18243813

RESUMO

BACKGROUND: Defibrillation threshold (DFT) testing has traditionally been a routine part of implantable cardioverter-defibrillator (ICD) implantation, despite a lack of compelling evidence that it predicts or improves outcomes. In the past, when devices were much less reliable, DFT testing seemed prudent; however, modern ICD systems have such a high rate of successful defibrillation that many electrophysiologists now question whether DFT testing is still worthwhile, particularly since DFT testing may now be the highest acute risk component of ICD implantation. OBJECTIVE: The purpose of this study was to systematically document complications directly attributable to intraoperative DFT testing. METHODS: We obtained data on DFT-related complications from all 21 adult ICD implant centers in Canada, covering the period from January 1, 2000, to September 30, 2006. RESULTS: There were a total of 19,067 ICD implants in Canada during the study period. There were three DFT testing-related deaths, five DFT testing-related strokes, and 27 episodes that required prolonged resuscitation. Two patients had significant clinical sequelae after prolonged resuscitation. CONCLUSIONS: The risk of severe complications from intraoperative DFT testing appears small, even allowing for the underestimation of its true rate with the current study methodology. These slight but measurable risks must be considered when assessing the risk-benefit ratio of the procedure. Additional data from ongoing prospective ICD registries and/or clinical trials are required.


Assuntos
Desfibriladores Implantáveis/normas , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Idoso de 80 Anos ou mais , Canadá/epidemiologia , Limiar Diferencial , Desenho de Equipamento , Análise de Falha de Equipamento , Segurança de Equipamentos , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Comportamento de Redução do Risco , Procedimentos Desnecessários